10-year warranty on carpet tiles, LVT and SPC Stockist in the UAE Free specification consultation

LVT vs SPC vs sheet vinyl for UAE commercial floors, compared on wear layer, fire and slip data

LVT vs SPC comes down to the core. LVT is a flexible vinyl plank or tile, laid click or glue-down. SPC adds a rigid stone-plastic core and floats on an attached pad. Sheet vinyl comes in heat-welded rolls for seamless hygiene floors. For commercial use, look for a 0.5 mm wear layer, R9 or better and a fire test report.

Urban Connect flooring teamUpdated 11 min read

On this page

Most comparisons of LVT and SPC online are written for homeowners and stop at "SPC is more rigid". A specifier needs more than that: the wear layer, the abrasion and castor chair results, the fire and slip classes, and what each floor does in a pantry, a patient room or a retail unit laid over old ceramic tiles.

This guide puts the values from our own Impression LVT and Artisan SPC datasheets next to typical commercial sheet vinyl, explains what each number means, and ends with a room-by-room table for UAE projects. Where a figure is an industry range rather than a datasheet value, we say so.

What LVT, SPC and sheet vinyl are made of

All three are PVC-based resilient floors. The differences are in the core, the format and how they are fixed, and those three things decide where each one works.

LVT (luxury vinyl tile) is built from flexible vinyl layers: a backing, a printed décor film, a clear wear layer and a UV coat. It comes as planks or tiles and is either glued to the subfloor or, in click formats, laid floating. Our range of Dubai LVT flooring includes both: Impression is a 5.0 mm click LVT, and the stone, wood, carpet and terrazzo design ranges are glue-down.

SPC (stone plastic composite) puts a rigid core of limestone powder and PVC under the same décor film and wear layer. Artisan SPC is a 5-layer build: UV coat, 0.5 mm wear layer, printed film, rigid SPC core and a 1.0 mm IXPE foam pad bonded to the back. It clicks together and floats, so it needs no adhesive. You will also see it sold as "rigid core" or "hybrid" flooring, and LVP (luxury vinyl plank) is simply LVT in plank format.

Sheet vinyl comes in rolls, typically 2 m wide, glued down with the seams heat-welded. Homogeneous sheet has the same material and colour through its full thickness. Heterogeneous sheet is layered, with a printed film under a clear wear layer. A full guide to homogeneous vs heterogeneous vinyl is coming soon.

WPC (wood plastic composite) has a foamed wood-plastic core. It is thicker and softer underfoot than SPC and dents more easily. We do not list WPC, so it is not covered further here.

LVT vs SPC vs sheet vinyl compared on datasheet values

On paper, Impression LVT and Artisan SPC carry the same wear layer and pass the same abrasion, castor chair and indentation tests. The real differences are the core, the 1.0 mm pad on the SPC, and how sheet vinyl handles water and hygiene.

PropertyClick LVT (Impression LVT)SPC (Artisan SPC)Sheet vinyl (typical commercial)
Overall thickness5.0 mm5.5 mm incl. 1.0 mm IXPE pad2.0 mm typical
Wear layer0.5 mm (20 mil)0.5 mm (20 mil)full thickness (homogeneous) or 0.7 mm typical (heterogeneous)
Coreflexible vinylrigid stone-plasticflexible vinyl
Fixingclick, floatingclick, floatingglued, heat-welded seams
Abrasion≥ 4,000 cycles, EN 13329≥ 4,000 cycles, EN 13329wear group T or P, EN 660-2 (typical)
Castor chair25,000 cycles, pass25,000 cycles, passuse class 34 typical (EN ISO 10874)
Residual indentation≤ 0.13 mm≤ 0.13 mmper product datasheet
Dimensional stability≤ 0.15%≤ ±0.2%per product datasheet
FireB1, GB 8624B1, GB 8624Bfl-s1, EN 13501-1 (typical)
Slip≥ R9, DIN 51130≥ R9, DIN 51130R9 to R10 (typical)
Waterplanks 100% waterproof, joints not sealed100% waterproofwaterproof when welded and coved
Impact soundΔLw 3 to 6 dB typical glue-down LVT; more with an approved underlayΔLw 15 to 20 dB typical with IXPEΔLw 13 to 19 dB typical, foam-backed grades
Emissionsformaldehyde, heavy metals and phthalates not detected; FloorScore, GreenTagformaldehyde and heavy metals not detected; FloorScoreproduct-specific
Light fastnesslevel 6not stated on the sheetper product datasheet
Warranty10 years10 yearsproduct-specific
Best foroffices, retail, hotel roomsapartments, retail, fast overlays on tilesclinics, labs, schools, wet rooms

Sheet vinyl figures are typical for commercial grades, not one product. Always check the datasheet of the exact sheet being specified.

The bottom line: if the room is dry and the subfloor is sound, LVT and SPC perform alike on wear, so choose on fixing method, acoustics and speed. If the room is washed down or has clinical hygiene rules, welded sheet vinyl is the floor.

Which wears better under office chairs and heavy footfall

With the same 0.5 mm wear layer and the same test results, Impression LVT and Artisan SPC wear at the same rate. SPC's rigid core gives it an edge against dents from heavy point loads; welded sheet vinyl in a high use class matches both on wear and adds seamless cleaning.

Here is what each datasheet number means on site:

  • 0.5 mm (20 mil) wear layer. The clear layer that protects the print. 0.3 mm is common in residential products; 0.5 mm is the usual starting point for commercial traffic in offices and retail.
  • Abrasion ≥ 4,000 cycles (EN 13329). The number of turns of an abrasive wheel before the print starts to wear through. Higher is better, and 4,000 cycles is in the band used for heavy commercial floors.
  • Castor chair 25,000 cycles, pass. A loaded office chair is rolled over the floor 25,000 times; a pass means no visible damage or delamination. This matters in every open-plan office. Pair it with soft (type W) castors on hard floors.
  • Residual indentation ≤ 0.13 mm. How deep a mark stays after a heavy load is lifted. A value this low means a filing cabinet or desk leg will not leave a lasting pit in normal use; use furniture cups under very heavy items on any vinyl floor.
  • Dimensional stability. The change in size after a heat test: ≤ 0.15% for Impression and ≤ ±0.2% for Artisan. Both are tight. On a 1.22 m plank, 0.2% is under 2.5 mm.

For sheet vinyl, ask for use class 34 (very heavy commercial) under EN ISO 10874 and wear group T or P under EN 660-2. Group T loses the least material in the test, so it suits corridors and wards with constant trolley traffic.

How fire and slip ratings compare for LVT, SPC and vinyl

Impression LVT and Artisan SPC both test at B1 to GB 8624 and at least R9 to DIN 51130. Typical commercial sheet vinyl tests at Bfl-s1 to EN 13501-1 and R9 to R10. The fire results come from different test systems, so they cannot be read across from one to the other.

Fire. GB 8624 is the Chinese classification for the burning behaviour of building materials, and B1 is its "difficult to ignite" class. EN 13501-1 is the European system; for floors it runs from A1fl to Ffl, and Bfl-s1 means very limited flame spread and low smoke. The two standards use different tests, so there is no official equivalence between B1 and Bfl-s1. If a consultant or authority asks for an EN 13501-1 or ASTM E648 class, ask for that specific test report rather than converting. A guide to Civil Defence fire ratings for flooring is coming soon.

Slip. DIN 51130 is a ramp test with oily shoes. R9 means the tester stayed upright on a ramp of 6° to 10°, R10 on 10° to 19°, and R11 on 19° to 27°. R9 suits dry offices, shops and hotel rooms. Wet areas, entrances in the rain season and ramps need R10 or higher, which points to safety vinyl rather than LVT or SPC. Our vinyl flooring options cover sheet and safety grades for those rooms.

Is LVT or SPC waterproof enough for UAE pantries and washrooms

Both are fine in a pantry. Neither belongs in a shower or wet room. The planks resist water; the joints of a floating floor do not.

Impression LVT planks are 100% waterproof, but the click joints are not sealed, so standing water can reach the subfloor. Artisan SPC is also 100% waterproof, and its rigid core does not swell, so it handles wet mopping and the odd spill in a pantry, a break-out kitchen or a coastal apartment. In both cases, wipe up standing water and keep the floor out of rooms that are hosed down.

For a washroom, shower area or wet clinical room, specify welded sheet vinyl with coved skirting turned up the wall. The welded seams and cove make one continuous surface with no joint for water to find.

Glue-down vs floating LVT and SPC for commercial floors

Click LVT and SPC float, which makes them fast to lay and easy to lift. Glue-down LVT is fixed to the subfloor, which makes it the safer choice for heavy rolling loads, very large rooms and floors in strong sun behind glazing.

Impression LVT and commercial SPC flooring such as Artisan are click-lock floating floors. Artisan's click joint is rated at ≥ 4.0 kN/m (ISO 24334) and its pad is attached, so the floor goes straight down over a sound, level subfloor. SPC can also be laid over existing ceramic tiles once loose tiles are fixed and grout lines are within the flatness the datasheet allows. On a retail refit that saves demolition, debris and screed drying time.

Our LVT design ranges (stone, wood, carpet and terrazzo) are glue-down. Choose glue-down where:

  • pallet trucks, hospital beds or heavy trolleys roll across the floor;
  • one open floor runs long distances without walls to break it up;
  • floor-to-ceiling glazing puts direct sun on part of the floor.

On that last point, the lab figures for Impression (≤ 0.15%) and Artisan (≤ ±0.2%) are close. In practice, a rigid core resists the gapping and peaking that a flexible floating plank can show when one strip of floor heats in afternoon sun while the rest stays air-conditioned. So in front of big windows, use SPC or glue-down LVT, and leave the expansion gap the datasheet asks for (8 to 10 mm is typical for floating floors). A full guide on how to choose LVT by wear layer and fixing method is coming soon.

How LVT, SPC and vinyl compare for impact sound

SPC with an attached IXPE pad cuts impact sound to the room below the most: typically ΔLw 15 to 20 dB. Foam-backed sheet vinyl is close at about 13 to 19 dB. Glue-down LVT on its own gives only about 3 to 6 dB. All three are typical ranges; ask for the tested value of the exact product.

ΔLw measures how much a floor covering reduces footstep noise heard in the room underneath. It does not measure the noise you hear in the same room. That explains the common complaint that SPC is "noisy": a rigid floating plank can sound hollow or clicky underfoot, especially with hard heels, even while it protects the flat below. An attached pad helps, and so does a flat subfloor, because a floating floor over dips drums more.

In apartment blocks and hotels, check the developer's or operator's acoustic target before choosing. In open-plan offices, carpet tiles still beat any vinyl floor for noise in the room itself.

Which floor to use in each room of a UAE project

Use this table as a first pass. It assumes a sound, dry subfloor and normal commercial traffic.

Room (UAE project)First choiceWhyAvoid
Open-plan officecarpet tiles or click LVTacoustics, castor chairsnone
Reception and corridorsglue-down LVTrolling loads, design rangesfloating floors in long runs without expansion breaks
Pantry and break-outLVT or SPCwater-resistant planks, easy cleaningcarpet
Patient room, clean utility, labhomogeneous sheet vinyl, welded and covedseamless, cleanable surfaceclick floors
Classroom, nurseryLVT or sheet vinyldaily wet cleaning, low emissionsnone
Retail floor over existing tilesSPCfloats over ceramic, no demolitionglue-down on uneven tiles
Apartment with full-height glazingSPC, or glue-down LVTrigid core resists sun movement; glue-down holds in placefloating LVT laid without acclimatisation

For a clinic or school, check the local authority's design guidelines (DHA, DoH or ADEK) for floor finish requirements before you fix the specification.

Where LVT, SPC and vinyl stop being the right choice

Resilient floors cover most commercial rooms, but there are places where another floor does the job better.

  • Car showrooms and heavy point loads. Vehicle tyres, jacks and display plinths call for porcelain, resin or polished concrete. See our full SPC flooring vs porcelain tiles comparison.
  • Wet rooms and showers. No floating floor. Use welded sheet vinyl or tiles.
  • Ballrooms and large hotel function rooms. Carpet, for acoustics and comfort over long events.
  • Rooms where the client wants real timber. Engineered wood. An SPC vs laminate and wood guide is coming soon.

Cost rarely decides between LVT and SPC on its own, as the two sit in similar ranges. Our guide to LVT and SPC prices gives typical UAE figures per m², supply only and installed.

FAQ

Is SPC the same as LVT?

No. Both are vinyl-based and can carry the same wear layer, as Impression LVT and Artisan SPC do (0.5 mm). SPC has a rigid stone-plastic core; LVT is flexible. That changes how they lie over uneven floors, how they sound and how they are fixed.

Is SPC better than LVT for commercial use?

It depends on the room. SPC suits fast overlays on existing tiles and sun-exposed rooms. Glue-down LVT suits heavy rolling loads and very large areas. Click LVT suits offices and retail where design range and a thinner floor matter.

Does SPC need underlay?

Not Artisan SPC: its 1.0 mm IXPE pad is attached, and adding another underlay can strain the click joints. For click LVT such as Impression, use only an underlay the datasheet approves.

What is the difference between SPC and WPC?

WPC has a foamed wood-plastic core, so it is thicker and softer underfoot. SPC is denser and resists dents from furniture and point loads better.

Vinyl or linoleum for a clinic?

Linoleum is made from natural materials such as linseed oil and wood flour, and it needs its protective finish maintained. Welded homogeneous sheet vinyl is the common choice in UAE clinics because it is seamless, coves up the wall and takes daily disinfectant cleaning.

Sources

  1. Urban Connect datasheets: Impression LVT (5.0 mm, 0.5 mm wear layer, EN 13329 ≥ 4,000 cycles, castor chair 25,000 cycles, residual indentation ≤ 0.13 mm, dimensional stability ≤ 0.15%, GB 8624 B1, DIN 51130 ≥ R9, light fastness 6); Artisan SPC (5.5 mm incl. 1.0 mm IXPE, 0.5 mm wear layer, ISO 24334 click strength ≥ 4.0 kN/m, dimensional stability ≤ ±0.2%, GB 8624 B1, DIN 51130 ≥ R9).
  2. EN 13329:2016+A2:2021, laminate floor coverings, specifications, requirements and test methods (abrasion test).
  3. EN 13501-1:2018, fire classification of construction products and building elements.
  4. GB 8624, classification for burning behaviour of building materials and products (the 2012 edition uses class B1; a 2025 revision has been published, so confirm which edition a test report uses).
  5. DIN 51130:2014, testing of floor coverings, determination of the anti-slip property (ramp test).
  6. EN ISO 10874:2012, resilient, textile and laminate floor coverings, classification.
  7. EN 660-2, resilient floor coverings, determination of wear resistance (Frick-Taber test).
  8. Manufacturer literature for typical sheet vinyl values and impact sound reduction (ΔLw), labelled typical.