Flooring specificationsUAE projects
Flooring fire and slip ratings explained with the test values from our own spec sheets
What each rating on a flooring datasheet means, and which values our carpet tiles, LVT and SPC were tested to.
- Spec sheets per collection
- Test standard named for every value
- Updated 10 November 2026
Test data from our own spec sheets.
- Fire result on our carpet tiles
- ASTM E648 Class I
- DIN 51130 slip on Impression LVT
- R9
- Quick Ship collections covered
- 6
- Combined team experience
- 55+ years
On this page
How to read a flooring datasheet before you write it into a UAE specification
A flooring datasheet answers five questions: will it pass the fire code, is it safe underfoot, will it last in this traffic, will it stay flat and stable, and is it healthy indoors. Check that every value names its test standard and belongs to the exact collection you are specifying, not the category.
| What you check | Fields on the sheet | Section below |
|---|---|---|
| Fire safety | Radiant panel class, national fire class, smoke density | Fire and smoke |
| Safety underfoot | Slip class or pendulum value | Slip resistance |
| Life in traffic | Wear layer, use class, abrasion, castor chair, pile weight | Wear and use class, carpet tile construction |
| Comfort | Static, impact sound | Static, impact sound |
| Stability | Dimensional stability, indentation | Stability |
| Indoor air | Formaldehyde, VOC, phthalates, certifications | Indoor air |
What ASTM E648 Class I, GB 8624 B1 and smoke density mean on a flooring sheet
ASTM E648 (radiant panel) measures how much radiant heat a floor covering can take before flame spreads along it, as critical radiant flux in W/cm². Class I is 0.45 W/cm² or more, Class II is 0.22 to 0.44 W/cm². Higher is better. Corridors and exits in many codes call for Class I.
GB 8624-2012 is the Chinese fire classification used by many Asian manufacturers. B1 is its "difficult to ignite" class. EN 13501-1 is the European system, where floors are classed A1fl to Ffl with a smoke suffix (s1 or s2); Bfl-s1 and Cfl-s1 are common commercial targets.
ASTM E662 measures optical smoke density in a closed chamber. A maximum of 450 is the limit most specifications use.
| Range | ASTM E648 | GB 8624 | ASTM E662 smoke | Source |
|---|---|---|---|---|
| Inception carpet tiles | Class I | B1 | Under 450 | Spec sheet |
| Element carpet tiles | Class I | B1 | Under 450 | Spec sheet |
| Crystaspun and Threadeon carpet tiles | Class I | B1 | Under 450 | Spec sheet |
| Impression LVT | Not on sheet | B1 | Not on sheet | Spec sheet |
| Artisan SPC | Not on sheet | B1 | Not on sheet | Spec sheet |
The class your project needs is set by the UAE Fire and Life Safety Code and the authority having jurisdiction, through your fire consultant. We do not claim a Civil Defence approval or an EN 13501-1 class for these ranges; ask us if your tender needs one.
How DIN 51130 R ratings and pendulum values compare for flooring slip resistance
DIN 51130 is a ramp test: a person in safety boots walks on an oiled sample while the ramp tilts, and the angle where they slip sets the class. R9 is the lowest class and suits dry interiors such as offices, hotel rooms and classrooms. Wet or greasy areas need a higher class.
| Class | Slip angle | Typical areas (industry guidance) |
|---|---|---|
| R9 | 6 to 10° | Offices, hotel rooms, classrooms, dry corridors |
| R10 | 10 to 19° | Washrooms, entrances, staff kitchens |
| R11 | 19 to 27° | Commercial kitchen prep areas, wet changing rooms |
| R12 | 27 to 35° | Commercial kitchens with grease, cold stores |
| R13 | Over 35° | Abattoirs, heavy grease areas |
Pendulum test (BS 7976, now EN 16165) gives a Pendulum Test Value (PTV) on a wet or dry floor. A PTV of 36 or more is generally read as low slip potential. Many UK and international consultants ask for it, because it can be tested on site after installation.
Our results: Impression LVT and Artisan SPC are R9 or better under DIN 51130. That fits dry interiors. For wet areas and kitchens, see commercial kitchen flooring and ask for a product whose sheet states R10 or higher.
Which LVT wear layer and use class you need for commercial traffic
The wear layer is the clear top film that protects the print on LVT and SPC. For commercial floors, 0.5 mm (20 mil) is the usual minimum; 0.3 mm suits homes and light commercial rooms. Impression LVT and Artisan SPC both have a 0.5 mm wear layer.
Use class (EN ISO 10874) grades resilient and textile floors by traffic: class 23 is heavy domestic, 31 to 33 are light to heavy commercial, and 34 is very heavy commercial. Ask for class 33 or 34 in malls, airports and school corridors.
| Test on our LVT and SPC sheets | Result | What it tells you |
|---|---|---|
| Abrasion (EN 13329) | ≥ 4,000 cycles | Resistance of the surface to wear-through |
| Castor chair | 25,000 cycles, pass | Office chairs roll without damage |
| Residual indentation | ≤ 0.13 mm | Furniture legs leave no lasting dent |
| Light fastness | Level 6 | Colour holds under daylight |
Source: Impression LVT and Artisan SPC spec sheets. See our LVT flooring specifications for formats and colours.
How pile weight, gauge and yarn decide carpet tile performance in heavy commercial use
Four numbers predict how a loop pile carpet tile will wear: pile weight (more yarn per m² wears longer), gauge (rows per inch across), stitches per inch (density along the row) and yarn. Solution-dyed nylon 6 carries colour through the fibre, so it holds colour under cleaning and sunlight.
| Collection | Pile weight | Gauge / stitches | Pile height | Backing | Size |
|---|---|---|---|---|---|
| Inception | 580 g/m² (16 oz/yd²) | 1/12, 10 per inch | 3.0 to 5.0 mm | PVC with fibreglass | 50 x 50 cm |
| Element | 17 oz/yd² | 1/12, 10 per inch | 2.0 to 6.5 mm | UltraEco | 50 x 50 cm |
| Forest Whisper | 16 oz/yd² | 1/12, 9.5 per inch | 3.3 to 6.1 mm | UltraEco | 50 x 50 cm |
| Crystaspun | 23 oz/yd² | 1/12, 6 per inch | 4.0 to 7.0 mm | UltraEco Pro | 60 x 60 cm |
All four are multi-level loop, 100% solution-dyed nylon 6, rated heavy commercial on their sheets. Compare all 12 collections by carpet tile types.
What the AATCC-134 static rating on a carpet tile means for offices
AATCC-134 measures the static charge a person builds up walking on carpet. About 3.5 kV is the level most people start to feel a shock, so 3.5 kV or less is the usual office target. Rooms with sensitive equipment often ask for 2.0 kV or less.
Our carpet tiles test at ≤ 3.5 kV with life-of-carpet static protection. For server or control rooms, ask for a conductive product with its own sheet.
How impact sound ratings compare across carpet tiles, LVT and SPC
Impact sound reduction (ΔLw), tested to ISO 10140-3 and rated to ISO 717-2, shows how much a floor covering cuts footfall noise to the room below, in dB. Higher is quieter. It matters in hotels, apartments and offices over occupied floors.
| Floor type | Typical ΔLw (industry ranges, not our test values) |
|---|---|
| Loop pile carpet tiles | 20 to 30 dB |
| Glue-down LVT | 3 to 6 dB |
| Click SPC with attached acoustic underlay | 15 to 20 dB |
| Sheet vinyl with foam backing | 13 to 19 dB |
Our sheets do not state a ΔLw value. Artisan SPC has a 1.0 mm IXPE underlay attached, which is the layer that gives click floors their sound reduction. Ask for the manufacturer's acoustic report if your consultant needs a number.
Why dimensional stability matters for SPC and LVT in UAE buildings
UAE buildings swing between cooled interiors and hot, humid site conditions before handover. Dimensional stability shows how much a plank grows or shrinks with heat: Impression LVT tests at ≤ 0.15% and Artisan SPC at ≤ ± 0.2%. Keep air conditioning running before and after installation, and leave the expansion gap the fitting guide asks for.
What formaldehyde, VOC and phthalate results mean on flooring sheets
Impression LVT and Artisan SPC test with formaldehyde, heavy metals and phthalates not detected, and Impression holds FloorScore and GreenTag certification. Inception carpet tiles reach JC/T 1074-2008 Class I for formaldehyde purification. For certifications, recycled content and EPDs, see recycled content and EPDs.
Which flooring ratings matter most for hospitals, gyms and offices in the UAE
| Sector | Ratings to check first | Read more |
|---|---|---|
| Hospitals and clinics | Welded seams, chemical resistance, slip, fire | hospital flooring in Abu Dhabi and welded vinyl flooring |
| Gyms and fitness | Shock absorption, thickness, slip, impact sound | gym flooring in Abu Dhabi |
| Offices | Castor chair, static, impact sound, pile weight | Corporate office flooring (via commercial flooring hub) |
| Hotels | Fire, impact sound, colourfastness | Hospitality flooring (via hub) |
For every floor type we supply, see our full flooring range.
Flooring specification questions from UAE architects and consultants
What fire rating does commercial flooring need in the UAE?
It depends on the space and the authority's reading of the UAE Fire and Life Safety Code. Corridors and exits usually need the best floor class, such as ASTM E648 Class I or EN 13501-1 Bfl-s1. Your fire consultant confirms the class. Our carpet tiles are tested ASTM E648 Class I.
Is R9 slip resistance enough for an office or a hotel corridor?
Yes, for dry interiors R9 is the usual minimum under DIN 51130. Entrances, washrooms and kitchens need R10 or more, or a wet pendulum value of 36 or higher. Impression LVT and Artisan SPC are rated R9.
What wear layer should commercial LVT have?
Use 0.5 mm (20 mil) or thicker for commercial rooms. A 0.3 mm layer suits homes and light use. Impression LVT and Artisan SPC both carry a 0.5 mm wear layer and pass a 25,000-cycle castor chair test.
Do the test results on one datasheet apply to the whole product type?
No. Each value belongs to the tested collection only. Always ask for the sheet of the exact range and colour you specify. Find more answers in our frequently asked questions.
Need flooring test data for a UAE submittal?
Tell us the space, the code your consultant works to and the ranges you are comparing. We send the matching sheets and samples, with a free consultation on the specification.